CONFIG_FXOS8700_PULSE_WIND:

The maximum interval of time that can elapse after the end of the latency interval in which the start of the second pulse event must be detected provided the device has been configured for double pulse detection. The detected second pulse width must be shorter than the time limit constraint specified by the PULSE_TMLT register, but the end of the double pulse need not finish within the time specified by the PULSE_WIND register. The resolution depends upon the sample rate (ODR) and the highpass filter configuration (HP_FILTER_CUTOFF[pls_hpf_en]). For ODR=800 Hz and pls_hpf_en=0, the resolution is 1.25 ms/LSB.

Symbol:

FXOS8700_PULSE_WIND

Type:

hex

Value:

“”

User value:

(no user value)

Visibility:

“n”

Is choice item:

false

Is defined:

true

Is from env.:

false

Is special:

false

Ranges:
  • [0, 0xff]
Prompts:
  • “Pulse window”
Default values:
  • 0x3c (value: “n”)
  • Condition: (none)
Selects:

(no selects)

Reverse (select-related) dependencies:
 

(no reverse dependencies)

Additional dependencies from enclosing menus and ifs:
 

FXOS8700_PULSE && FXOS8700_TRIGGER (value: “n”)

Locations:
  • ../drivers/sensor/fxos8700/Kconfig:199